Maintenance
and setting
Inspection before every casting process
• Check the funnel between the two chambers for casting
residues and clean if necessary.
• Check the tip of the electrode (N) and grind it to the correct
shape if necessary.
• Use only a dry clean crucible and dry clean ceramic seals.
• Sand-blast seriously oxidised crucibles and electrodes in the
sand blaster.
Clean copper crucibles and electro-
des thoroughly after sand blasting.
If work on electrical components
or conductors is required, always
seek the help of a second person
to operate the main switch if
necessary.
Replacing the electrode (N)
• Loosen the electrode clamp with a wrench (A/F 7 mm)
• Remove the electrode from the clamp.
• Grind the tip of the electrode to the correct shape
(see page B 18).
• Replace the electrode and tighten the electrode clamp (M).
Removing the funnel (T)
• Using the pin pliers, release the ring nut in ceiling of the
casting chamber
• Remove the funnel upwards
When replacing the funnel, tighten the ring nut.
Observe the position of the ring nut. Do not forget the O
ring.
autocast universal
®
230 Casting System Maintenance and setting Stand 1. 9. 03 B 27
¡