Diamond Systems Tritan Instruções de Operação Página 34

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 90
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 33
autocast universal
®
230 Casting System Accessories and replacement parts Stand 1.9. 03 A 27
Trimming of titanium castings with
the rematitan
®
finishing kit
Note on safety
– Always wear safety goggles when finishing
castings.
– Always turn on the extractor unit during work.
– The maximum rotation speeds of the various
instruments must not be exceeded
Description
Pure titanium is a soft tough material which requires special pro-
cedures for finishing and polishing. The Finishing Set
(Ord.-No. 135-500-00) contains the most important materials
for the efficient finishing and polishing of titanium for dental
purposes.
The sequence of use and the most important finishing
characteristics of the individual instruments are described
below.
General Notes
– Use the finishing materials for titanium only
– The grinding tools must not become clogged.
This precludes the use of other types of tool
(e.g. diamonds) for finishing purposes.
– In addition, local overheating of the workpiece must be
avoided. For this reason, care must be taken when using
rubber polishers.
– Do not exert too much pressure and work at low speeds.
Preliminary operation
Titanium castings are always covered by an oxide skin
which must be removed carefully before work begins.
This is done with the blasting unit and blasting medium
of various grades.
Note: Sparks are always created when finishing titanium.
When using rematitan
®
Plus investment material:
Model casting: blasting type Al
2
O
3
blast (< 250 µm)
Crowns and bridges: blasting type Al
2
O
3
blast (< 125 µm)
Important: Do not damage the edges of the crown.
Do not exert too much pressure.